A complete catalog of disposable, patented orthopedic surgical instruments organized across six product categories — supporting autologous bone grafting, arthroscopic cartilage management, fluid management, graft delivery, joint access, and bone graft stabilization for the shoulder, hip, and knee.
Minimally invasive instruments for harvesting structural cancellous bone and bone marrow from the iliac crest for use as autologous graft material.

OSI's legacy harvesting instrument, designed for harvesting structural cancellous cores of bone. Bone marrow is simultaneously harvested when attached to the Bone Saver. Provides vertical support in the treatment of tibial plateau fractures.

A one-of-a-kind harvesting tool that reaches deep into the ilium to morselize cancellous bone while simultaneously aspirating it for collection by the Bone Saver. Harvested bone is filtered and super-concentrated along with healthy bone-forming cells. Skin incision ≤2mm; harvest depth to 40mm; sweep angle >60°.

A removable inline filter element for the Bone Saver. Once filled with morselized bone and bone marrow, the filter may be wrapped with a dry laparotomy pad to remove excess blood through activation of plasmin — super-concentrating the bone and bone marrow.

OSI's legacy collection device with an inline filter that collects large quantities of bone and bone marrow using the Beacon Biomass Harvesting Trephine or the Bone Tool. Vacuum-assisted, eliminating the need for off-table centrifugation.
OSI's largest product category — arthroscopic visualization, portal access, debridement, ablation, and microfracture instrumentation supporting joint preservation procedures of the shoulder, hip, and knee.

Available in Q3mm, Q4mm, and Q5mm configurations (30°/0°). The Q3/Q4 are housed within a single inflow arthroscopic sheath designed for superior maneuverability and visibility; the sheathless Q5 acquires illuminated anatomic structures and non-digital 3D images. Designed for use with the OSI Clear Cannula in shoulder, hip, and knee arthroscopy, including intraosseous endoscopy during core decompression.

A detachable guide for precise needle localization within the joint to establish a second arthroscopic portal.

A smooth-surfaced, directionally-seamed cannula that facilitates precise second-portal placement and increases the luminosity of the Q Arthroscope. The first and only cannula of its kind to provide real-time images in the z-axis, minimizing extravasation and soft-tissue swelling.

A low-pulse tissue ablation and cautery device that concentrates electron emission at the tip of the probe. Inline suction keeps the operative field clear, and the device attaches to a standard generator, eliminating the need for special equipment.

A handheld, serrated curette designed for configurable, aggressive debridement of the posterior knee and other hard-to-reach areas, including the anteromedial humeral head in the shoulder joint. Inline suction removes all debris.

A handheld, smooth curette designed for configurable, smooth-surface debridement of the tibial plateau and curvilinear femoral condyle.

A patented outflow adaptor that engages the Angler or the Red Belly. Its rotational engagement mechanism allows the configured curette to be positioned precisely in any hard-to-access area.

Designed to variably penetrate subchondral bone at areas of cartilage loss. The short version supports articular surface microfracturing of the knee; the extended version supports non-articular intraosseous subchondral microfracturing of AVN and bone marrow edema lesions.
Comprises a precision 4mm cannula with a targeting guide for the Q 3mm arthroscope and a shortened arthroscopic sheath for non-digital 3D imaging — used for posterior knee visualization during meniscus root repair or debridement.
Burrs of Prey® Unshrouded Debridement System
OSI's patented unshrouded burrs are designed for intraarticular saucerization and micro chondroplasty, each shaped for a specific anatomic access challenge.

Smooth-surfaced burr that captures frayed pieces of cartilage, characterizing a true micro chondroplasty. Used for hip arthroscopy and micro chondroplasty at the acetabular rim.

Ideal for sub-meniscus micro chondroplasty and meniscus root debridement, and for rapid micro chondroplasty in the patellofemoral sulcus.

Ideal for sub-labral pincer debridement — debrides the chondrolabral junction and central acetabular osteophytes for CAM lesion management without detaching the labrum.

A smooth, curvilinear head designed to smooth over areas of chondromalacia.

Round-headed burr ideal for backstroke debridement of the medial margin of the sourcil and traditional CAM lesions.

Long, cylindrical shape ideal for rapid removal of prominent osteophytes along the anterior, medial, and lateral osteochondral junctions of the femoral condyles during intraarticular saucerization of the knee.
Inflow and outflow tubing systems that maintain a clear visual field throughout arthroscopic procedures.

Comprises Y-connectors and accessories for integration into any arthroscopic pump system. ArthroSelect Tubing provides single-portal inflow and outflow in the hip, shoulder, and knee under both gravity and suction modes, ensuring the visual field remains clear.
Low-pressure, syringe-free delivery systems for autologous bone marrow aspirate and cancellous bone graft.

A unique product designed for low-pressure delivery of any selected amount of bone marrow aspirate and viscous cancellous bone graft. Auto-concentration technology allows for syringe-free, handheld delivery of any graft composite. Used with the OSI Irrigation Needle, which removes oxLDL, fat, and inflammatory cytokines from the host bed prior to grafting.

Shares the Biomass Delivery Trephine's low-pressure, auto-concentration, syringe-free delivery design. Used for subchondral and greater-tuberosity bone marrow edema lesions and aseptic loosening lesions; irrigation removes oxLDL, fat, and inflammatory cytokines from the host bed.

Directs an irrigation stream strategically within the host bed to remove oxidized LDL, fat, and inflammatory cytokines — used alongside the Biomass Delivery products for pre-grafting site preparation.

A simple but unique product for open or percutaneous delivery of morselized cancellous bone. The right-angle, side-loadable tray makes graft delivery safe, simple, and efficient, with dimensions configured for neutral-pressure graft delivery to avoid embolization.
Guidewires, needles, and depth probes supporting precise, minimally invasive joint access and portal placement.

Once inserted into the joint, accepts the 1.19mm Nitinol wire for quick and easy joint access. Also delivers bone marrow to cancellous grafts via the Hip Tool.

Dimensionally designed for coaxial insertion into the Biomass Delivery Trephine and Curette. Used for irrigation and aspiration of bone marrow edema lesions, host-bed preparation, and single-portal arthroscopy.

Smooth, blunt-tip design for joint insertion, completely avoiding the need for traditionally sharp or large-diameter trocars. Used with OSI dilators (5.4mm / 6.5mm / 8.5mm).

Designed for strategic placement within the femoral head, humeral head, or femoral condyles during core decompression with histopathologic analysis; used with the OSI Bone Coring Trephine.

Designed for lateral wall portal establishment during treatment of bone marrow edema lesions in patients with subchondral lesions, used with the Biomass Delivery Curette.

Freely passed through the Introducer Needle to facilitate arthroscopic shaver insertion and portal retention.

Designed for safely sounding the depth of bone and marrow harvesting sites when using the Beacon Biomass Harvesting Trephine.

Designed for gentle penetration into percutaneously accessed bone marrow edema lesions using the Biomass Delivery Trephine, aspirating oxLDL and cytokines prior to irrigation and graft placement.
Implantable stabilization systems that secure bone graft within the femoral or humeral head following core decompression and debridement for avascular necrosis (AVN).

Stabilizes bone graft within the femoral head after endoscopically guided core decompression and thorough debridement for AVN. Stabilization allows early postoperative passive range of motion and more extensive debridement consistent with removal of the avascular burden. Implant angles 125°–140°; removable hardware.

Stabilizes bone graft within the humeral head after endoscopically guided core decompression and thorough debridement for AVN, enabling direct joint-surface elevation. Implant angles 130°–140°; removable hardware.
Contracting officers and clinical procurement teams can request detailed product specifications, FDA registration documentation, and healthcare-professional product information directly from OSI.